Option Z Offset In Section Bltouch Must Have Minimum Of 0 0

Option Z Offset In Section Bltouch Must Have Minimum Of 0 0. Collectie 55 Ender 3 Bltouch Z Offset I already inserted a line in [probe] as suggested at another place The trigger point of the BL-Touch obviously has to be closer to the bed as the nozzle

HowTo ZOffset and Tramming on Creality CR10 V2 with BLTouch YouTube
HowTo ZOffset and Tramming on Creality CR10 V2 with BLTouch YouTube from www.youtube.com

If your controller board needs the fixed 5V high logic level of the 5V mode you may set the 'set_output_mode' parameter in the [bltouch] section of the printer config file to "5V". I also noticed you have 2 z motors but that they have 2 different step_distance values, shouldnt they be the same?

HowTo ZOffset and Tramming on Creality CR10 V2 with BLTouch YouTube

[bltouch] sensor_pin: P0.10 # Pull-up (^ symbol) needed in open drain mode control_pin: P2.0 # Some BLTouch V3 and many clones apparently require this, though mine didnt: pin_up_touch_mode_reports_triggered: true #flavor: genuine_smart_3.1 x_offset: -43 y_offset: -10 # z_offset = 1.199 pin_move_time: 1 samples: 2 # Set z offset = -1.001 after testz=-4 #*# <----- SAVE_CONFIG -----> #*# DO NOT. Basic Information: Printer Model: ender 3 v2, bltouch MCU / Printerboard: 4.2.2 printer.cfg (6.7 KB) klippy.log (2.7 MB) Describe your issue: after a months of running the printer fine i started to notice that the offset was a bit off Any suggestions, ideas? Also, forgot to mention I saw another post talking about min position on z, however I already have that set:

Cannot save configuration. Keep getting error `Option 'z_offset' in section 'bltouch' must have. [bltouch] sensor_pin: P0.10 # Pull-up (^ symbol) needed in open drain mode control_pin: P2.0 # Some BLTouch V3 and many clones apparently require this, though mine didnt: pin_up_touch_mode_reports_triggered: true #flavor: genuine_smart_3.1 x_offset: -43 y_offset: -10 # z_offset = 1.199 pin_move_time: 1 samples: 2 # Set z offset = -1.001 after testz=-4 #*# <----- SAVE_CONFIG -----> #*# DO NOT. so i thought lets run probe_calibrate within the command pallet of the fluidd ui

Ender 3 V2 Bltouch Z Offset. If your controller board needs the fixed 5V high logic level of the 5V mode you may set the 'set_output_mode' parameter in the [bltouch] section of the printer config file to "5V". SAVE_CONFIG section 'bltouch' option 'z_offset' conflicts with included value SAVE_CONFIG section 'extruder' option 'pid_Kp' conflicts with included value Background The SAVE_CONFIG command updates various aspects of the printer.cfg